SD-WWTP Animated Centrifuge Deception Demo
Wastewater sludge dewatering scenario showing actual process behavior versus malware-masked operator values.
Scenario Phase
Baseline Operations
Real Equipment Condition
Healthy
Operator HMI View
Normal
Animated DCS Graphic: Dewatering by Centrifuge
Phase 1
Nominal operation
Popup closed
T+00:00

DEWATERING BY CENTRIFUGE

Sludge Dewatering System
FROM THICKENER /
DIGESTER
DEWATERED SOLIDS
(SLUDGE CAKE)
FLOCCULANT
PIT
101
Sludge Feed
Pressure
3.2
bar
FIT
101
Sludge Feed
Flow
18.7
m³/h
QSS
101
Solids Content
(Feed)
2.45
%
FIT
201
Flocculant Flow
2.6
L/h
FIT
301
Centrate Flow
22.4
m³/h
QDENS
101
Sludge Density
(Alternative)
1.045
g/cm³
PROCESS DATA INTEGRITY WARNING
Centrifuge Out of Order
Mechanical damage suspected. Inspection required before restart.
Actual Process Values
Bowl Speed2,860 rpm
Differential Speed18 rpm
Feed Flow18.7 m³/h
Flocculant Flow2.6 L/h
Solids Content2.45 %
Vibration0.8 mm/s
Bearing Temperature68 °C
Damage Index0 %
Trip StatusNo Trip
Field reality
Spoofed Operator Display
Bowl Speed2,860 rpm
Differential Speed18 rpm
Feed Flow18.7 m³/h
Flocculant Flow2.6 L/h
Solids Content2.45 %
Centrate Flow22.4 m³/h
Cake Dryness21 %
Alarm BannerNo Active Alarms
Process StatusStable
Replay / masked values
Event Log